Breaking A Connection (Continued)
n) Aligntheopeningintherotarygearwiththemouthofthetongoncethejawsarefree.Openthetongdoorandguidethetong
awayfromthestring,andusetheliftcylindercontroltolowerittothedrillfloorifdesired.
IllustratIon 2.H.11: lowerIng tong usIng lIft CylInDer Control
RIG PERSONNEL MUST STABILIZE THE TONG AS IT IS LOWERED TO THE DRILL FLOOR
o) Useyourrig’sstandardpipehandlingprocedurestoremoveandrackthefreedtubingstand.
p) Repeatsteps“e”through“p”asmanytimesasnecessarytobreakoutandun-threadthedesirednumberofconnections.
H. EXTREME COLD WEATHER OPERATION PROCEDURES
1) Consultthepowerunitengineoperator’smanualforallcoldweatheroperatingproceduresandprecautions.
2) Selectgearandbearinglubricantsthatarecompatiblewithexpectedclimaticconditions.
3) Selecthydraulicfluidthatiscompatiblewithexpectedclimaticconditions.
4) Allowhydraulicfluidtocirculateforapproximately20minutesafterstartingthepowerunit,priortoactivatingthebypassvalve
toallowfluidtocirculatetotong.Ifthepowerunitisequippedwithanoiltemperaturegauge,ensurethatthefluidhasreached
operatingtemperatureasspecifiedbyhydraulicfluiddatasheet.
5) Allowforadequatedryingofmoisture(priortolubricating)whencleaningtongpartsincoldweather.
seTup & operaTion