MT100 Multipoint Flow Meter OPERATION
Command 50: Read Dynamic Variable Assignments
Byte
Format
Description
Request Data Bytes
None
Response Data Bytes
0
Unsigned-8
Device Variable assigned to the primary variable.
1
Unsigned-8
Device Variable assigned to the secondary variable.
2
Unsigned-8
Device Variable assigned to the tertiary variable.
3
Unsigned-8
Device Variable assigned to the quaternary variable.
Code
Class
Description
Response Codes
0
Success
No Command-Specific Errors
1–127
Undefined
Command 51: Write Dynamic Variable Assignments
Byte
Format
Description
Request Data Bytes
0
Unsigned-8
Device Variable assigned to the primary variable.
1
Unsigned-8
Device Variable assigned to the secondary variable.
2
Unsigned-8
Device Variable assigned to the tertiary variable.
3
Unsigned-8
Device Variable assigned to the quaternary variable.
Response Data Bytes
1
0
Unsigned-8
Device Variable assigned to the primary variable.
1
Unsigned-8
Device Variable assigned to the secondary variable.
2
Unsigned-8
Device Variable assigned to the tertiary variable.
3
Unsigned-8
Device Variable assigned to the quaternary variable.
Code
Class
Description
Response Codes
0
Success
No Command-Specific Errors
1
Undefined
2
Error
Invalid Selection
3–127
Undefined
Note: 1. The value returned in the response data bytes reflects the value actually used by the device.
Fluid Components International LLC 57