4 Electrical installation
24 Festo – GDCP-CMMP-M0-HW-EN – 1511c – English
Caution
Danger from unexpected movement
Faulty pre-assembled lines may destroy the electronics and trigger unexpected move
ments of the motor.
When wiring the system, use only the supplied plug connectors and preferably the
cables listed in the catalogue as accessories.
è www.festo.com/catalogue
Lay all flexible lines so that they are free of kinks and free of mechanical stress; if
necessary use chain link trunking.
Note
ESD (electrostatic discharge) can cause damage to the device or other system parts at
plug connectors that are not used.
Before installation: Earth the system parts and use appropriate ESD equipment (e.g.
shoes, earthing straps etc.).
After installation: Seal unassigned Sub-D plug connectors with protective caps
(available at authorized dealers).
Observe the handling specifications for electrostatically sensitive devices.