B.2 Diagnostic messages with instructions for fault clearance
Error group 0 Information
No. Code Message Reaction
0-0 - Invalid error Ignore
Cause Information: An invalid error entry (corrupted) was found in the
diagnostic memory marked with this error number.
The system time entry is set to 0.
Action
0-1 - Invalid error detected and corrected Ignore
Cause Information: An invalid error entry (corrupted) was found in the
diagnostic memory and corrected. The additional information con
tains the original error number.
The system time entry includes the address of the corrupted error
number.
Action
0-2 - Error cleared Ignore
Cause Information: Active errors were acknowledged.
Action
0-7 - Subsequent entry Ignore
Cause Information: è Diagnostic memory entry.
Action
0-8 - Controller switched on Ignore
Cause Information: è Diagnostic memory entry.
Action
0-22 - Default parameter record loaded Ignore
Cause Information: è Diagnostic memory entry.
Action
Error group 1 Stack overflow
No. Code Message Reaction
1-0 6180h Stack overflow PSoff
Cause Incorrect firmware?
Sporadic high processor load due to cycle time being too short
and specific processor-intensive processes (save parameter set
etc.).
Action Load an approved firmware.
Reduce the processor load.
Contact Technical Support.

Table of Contents

Other manuals for Festo CMMP-AS-C5-11A-P3-M0

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Festo CMMP-AS-C5-11A-P3-M0 and is the answer not in the manual?

Festo CMMP-AS-C5-11A-P3-M0 Specifications

General IconGeneral
BrandFesto
ModelCMMP-AS-C5-11A-P3-M0
CategoryController
LanguageEnglish

Related product manuals