5.6 Converting the CP valve terminal to
different electrical connections
Due to the modular structure of the CP valve terminal,
you can convert it to IC, MP, AS-i or CP connections.
Proceed as follows:
CP terminals with IC connection
Loosen the locking screws on the connecting
sockets.
Pull the socket carefully away from the connecting
lugs on the pilot solenoid coil.
Insert the MP, AS-i or CP connection onto the
connecting lugs of the pilot solenoid coils.
Fasten the connector plate with the 4 socket head
screws. Tighten the screws in a diagonally opposite
sequence.
5. Maintenance and conversion
5-20 CPV... 9802