5.2 Conversion from pushing to locking manual override
By removing a safety clip, you can convert your CP
terminal from pushing to locking manual override. Pro-
ceed as follows:
If you do not wish to use the safety clip again:
Use a screwdriver to press in the centre of the safety
clip, as shown in
1
. The safety clip will then bend
and can be removed from the fastening.
If you wish to use the safety clip again:
Use a thin object (e.g. a spatula) to lift the safety clip
out of the fastening as shown in
2
.
1
2
Remove the safety clip by pressing it out
Remove the safety clip by lifting it out (clip can be used again)
Fig. 5/5: Safety clip of the manual override
1
2
5. Maintenance and conversion
5-12 CPV... 9802

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Festo CP Series and is the answer not in the manual?

Festo CP Series Specifications

General IconGeneral
TypeController
SeriesCP
CategoryController
ManufacturerFesto
Operating Voltage24 V DC
Protection ClassIP20
Communication InterfaceCANopen, PROFINET
Programming EnvironmentFesto Automation Suite
Number of AxesVaries (depending on model, typically up to 6 or more)