EasyManua.ls Logo

Fiori DB 460 - Page 160

Fiori DB 460
252 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
160
6
OPTIONAL EQUIPMENT
id.:
DB 460 REV. 00 02/01/2015
6.2.5.
PRECAUTIONS FOR USE IN COLD CLIMATE CONDITIONS
If you have to work in ambient temperatures close to 0°C, the pump has to be operated without pressure for
one minute with the power jet cleaner open so that any ice that has formed can melt.
CAUTION: If the pump has frozen, do not operate it until the entire system has defrosted.
- Clean the pump with water mixed with a solution of antifreeze for radiators or an oily lubricating and anti-
oxidant solution.
- Do not operate the pump with cold oil.
- If the hoses have frozen, let them defrost before starting work.
- When you have nished work, disconnect the water inlet tube and fully discharge the pressure by holding the
regulating valve on the power jet cleaner open. Use the breather valve to drain out the residual water in the
pump cover.
6.2.6. SCHEDULED MAINTENANCE TABLE
POWER JET CLEANER PUMP
POWER JET CLEANER FILTER
- Pull the trigger of the power jet cleaner to discharge all the residual pressure in the tubes to ground.
CAUTION: If during use you notice that the pump becomes noisier and the jet discontinuous, it means
that it is taking in air. Immediately open the low-pressure nozzle B and correct the fault.
CAUTION: Use only nozzles with a fan-pattern jet to clean delicate surfaces, holding the nozzle 75cm
away from the surface to be cleaned.
CAUTION: In the event of malfunctioning, immediately contact the nearest AUTHORISED FIORI
WORKSHOP.
Description of the symbols used in the table:
= Check and repair = Replace
= Clean = Grease or lubricate
WORKING AREA
EVERY 8
HOURS OR
DAILY
REGULAR MAINTENANCE INTERVALS
EVERY 500
HOURS OR
12 MONTHS
EVERY 1000
HOURS OR
24 MONTHS
EVERY 2000
HOURS OR
48 MONTHS

Table of Contents