Maintainence
30.10.12 Kapitel/Chapter 7: Maintainence - Seite/Page 101
7.3 Environmental protection
Environmental protection.Danger to the environment due to mishandling!
Significant environmental damage can occur, particularly for
incorrect disposal, if environmentally hazardous operating
materials are mishandled. Therefore:
• Always observe the instructions mentioned below.
• Take immediate action if environmentally hazardous
materials reach the environment. Inform the responsible
local authorities about the damage in the case of doubt.
The disposal must be performed by a specialist disposal
company.
7.4 Maintenance Requirements
Control before starting
• Oil level
• Cooling system leaks
• Visual check for any changes, leaks oil drain system, v-belt,
cable connections, hose clips, air filter, fuel lines
Once a week
• Lubrication of actuator-trapezoid thread spindle
7.5 Maintenance interval
For the maintenance intervals, see the „General information for vehicles generators“ which are attached to this
manual.
For generators with dynamic maintenance interval (for example generators with iControl2). Further informations are
in the remote control panel manual/data sheet.
Note:
With the dynamic operation hours the service interval can be
raised up to 30% (200h max.). Make sure that the dynamic
operation hours are not reset accidently between the service
interval.
7.6 De-aerating of the coolant circuit
Particular hints for the de-aerating of the cooling system
If the coolant has been drained or if air has permeated into the cooling system by other reasons, a careful ventilation
of the cooling system is necessary. The de-aerating process has to be rerunned several times.