22.3.11 Grundlagen_deu.R01 - Kapitel/Chapter 3: Seite/Page 35
water up to the marking if necessary.
Today’s starter batteries are normally maintenance-free.
Deep discharge may damage the battery and may be useless afterwards.
Keep the battery clean and dry. Continuously clean the battery terminals (+ and -) and clamps and lubricate with an
acidfree and acid-resistant grease. Make sure there is a good contact of the clamp connections when assembling. If
voltage is approx. below 1,95 Volt, the cell should not decline the open-circuit voltage of the battery. This equates
approx. 2,1V / cell open-circuit voltage when battery is fully charged.
For a 12 V battery applies 11,7 V lower open-circuit voltage (battery flat) - conservation charging 13,2 V.
For a 24 V battery applies 23,4 V lower open-circuit voltage (battery flat) - conservation charging 26,4 V.
These data relate to a battery temperature of 20-25°C. Consider the specifications of the battery manu facturer.
Notice: Fischer Panda recommendation:
Install a battery main switch and turn it to the off-position.
(Disrupt the battery circuit)
Install a sufficient fuse in the positive battery line close to the
battery
Check contacts for corrosion on a regular basis.
3.4.2 Arrangements at a short-term standstill
Short-term standstill (1 to 3 months)
Measure the charge of battery via the open-circuit voltage
At stand still >7 days - disconnect the battery (e.g. put battery main switch to 0)
Within 2-3 months - let the engine run for at least 10 min
3.4.3 Arrangements at a medium-term standstill / winter storage
Medium-term stand still (3 to 6 months)
3.4.3.1 Arrangements for conservation:
Check the charge of battery and recharge approximately every 3 months if necessary. Consider the specifications
of the battery manufacturer.
Check anti-freeze protection of the cooling water and refill if applicable.
The anti-freeze protection should not be older than 2 years. The content of the anti-freeze protection should be
between 40% and 60% to ensure corrosion protection in the cooling water circuit; Refill anti-freeze if necessary.
If cooling water will be drained, for example after a conservation of the engine, no water should remain within the
engine during the stand still. At the control unit a correspondent note „NO COOLING WATER“ has to be placed.
Drain engine oil as required. Refill engine with conservation oil up to maximum at the oil dip stick.
Drain diesel fuel from tank and refill with conservation mixture (90% diesel and 10% conservation oil - up to max).
Let engine run for 10 min.
Remove v-belt as required and store packed at a dry place. Protect from UV radiation.
Attention!Cover alternator openings.
No cleaning fluids or preserving agents may enter the alter-
nator. Danger to destroy the alternator.