Maintenance Instructions
22.3.11 Panda PMS 8.000 NE - 42 NE Manual.R05 - Kapitel/Chapter 6: Maintenance Instructions Seite/Page 127
6.11 Checking the water separator in the fuel supply
Fig. 6.11-1: Pre-filter with water separatorThe pre-filter with water separator has a cock underneath, by which means
the water can be drained.
This water sinks to the bottom, due to the difference in the densities of water
and fuel. Water is heavier than the diesel
Sample picture
6.11.1 Ventilating the fuel system
Normally, the fuel system is designed to ventilate air itself i.e. as soon as the electric starter motor starts operation
the fuel pump starts working and the fuel system will be de-aerated after some time automatically. It is nevertheless
essential to ventilate the system prior to the first operation (as all hoses are empty) as follows:
1. Power switch "ON". Functional lights should light up.
Fig. 6.11.1-1: Failure Bypass Switch
2. Press failure bypass switch and keep firmly pressed.
The electrical fuel pump must be audible. Switching on
and off the solenoid valve at the generator will be audible
by pressing the failure bypass switch (if capsule remo-
ved).
Sample Picture