5.5.4 Connecting the pressure monitor
For gear units with mounted oil supply system or separate oil supply system, you must connect
the pressure monitor so that it functions correctly.
Further information
You can find additional information on pressure monitoring in the pressure monitor operating
instructions, provided in the complete gear unit documentation.
5.5.5 Connecting the heating element
Procedure
To connect heating elements to the gear unit, proceed as follows:
1. Check that the heating element connection is not damaged.
2. Install the electrical wiring for the heating elements.
Further information
Further information about the heating can be found in the heating operating instructions in the
complete documentation for the gear unit.
5.5.6 Connecting the oil-level monitoring system
Procedure
To connect the oil-level monitoring system to the gear unit, proceed as follows:
1. Ensure that the filling level limit switch connection is not damaged.
2. Electrically connect the filling level limit switch.
3. Connect the signal so that for the "oil level too low" signal, the drive motor cannot start and
an alarm is output.
Bypass this signal in operation.
Further information
Additional information about the oil-level monitoring system can be found in the operating
instructions for the oil-level monitoring system components provided in the complete gear unit
documentation.
You can find technical data in the separate data sheet and in the equipment list in the complete
gear unit documentation.
Assembly
5.5 Connecting components
Gear unit 5118en
70 Operating Instructions 10/2017