Intervals and time limits Measures
Every 2 years Carry out a general inspection of the gear unit
Check the cooling coil
Check that all of the fastening bolts are tight
Clean the fan and gear unit
Every 20 000 operating hours, at least every
4 years
Change the oil if using semi-synthetic oil of API Group
III, PAO or PG oil (or depending on the result of the oil
sample test)
6 years after the specified date of manufacture Change the hoses
Further information
Further information about additional maintenance and servicing work can be found in the
separate data sheet in the complete documentation for the gear unit.
Further information about installed components can be found in the operating instructions for
the components in the complete documentation for the gear unit.
8.3 Maintenance and servicing work
Introduction
You can find maintenance and servicing measures relating to gear unit lubrication and
preservation, which are not provided in this chapter, in BA 7300 in the complete gear unit
documentation.
8.3.1 Cleaning the venting screw
Cleaning interval
For dust deposits, you must clean the venting screw before the minimum interval of 3 months
expires.
CAUTION
Compressed air can cause injuries
There is a risk of eye injury when using compressed air.
Wear suitable safety goggles.
Servicing
8.3 Maintenance and servicing work