Possible faults Causes Possible remedies
Oil is foaming in the
gear unit
Preservation agent not completely
drained off
Change the oil
Oil supply system left in operation
for too long at low temperatures
Switch off the oil supply system
Degas the oil
Gear unit too cold in operation
Switch off the gear unit
Degas the oil
Start up without cooling water during cold restart
Water in the oil
Take test tube sample to examine oil condition for water
penetration
Have the oil examined by a chemical lab
Change the oil if necessary
Oil defoamer has run out
Examine the oil
Change the oil if necessary
Unsuitable mixture of oils
Examine the oil
Change the oil if necessary
Oil escaping from the
gear unit
Inadequate sealing of the housing
cover or joints
Check the seals and replace if necessary
Seal housing cover or joints
Check the compression seals and retighten screws if
necessary
Leaking pipes
Check the pipes, and replace or seal if necessary
Oil supply system mal‐
function
-
Read the operating instructions for the oil supply system