A Menu structure FLUXUS F808, F809
UMFLUXUS_F808_8091V1-2-1EN, 2019-08-23 173
SYSTEM settings\Storing
selection of the displays for the storing of measured values in the data logger
setting of the overflow behavior of the data logger x
selection of the storage mode
sample: storing and online transmission of the displayed measured value
average: storing and online transmission of the average of all measured val-
ues of a storage interval
x
setting of the storing behavior of the totalizers
one: the value of the totalizer that is currently displayed will be stored
both: one value for each flow direction will be stored
x
activation of the storing of the signal amplitude
The value will only be stored if the data logger is activated.
x
activation of the storing of the sound speed of the fluid
The value will only be stored if the data logger is activated.
x
activation of the storing of diagnostic values x
SYSTEM settings\serial transmis.
selection of the displays for the formatting of the serial transmission of mea-
sured values
activation of the serial transmission of data with/without blanks x
selection of the decimal marker for floating point numbers x
selection of the character for column separation x
selection of the serial interface
default: RS232
This display will only be indicated if the transmitter has an RS485 interface.
x
SYSTEM settings\Network
change of the settings of the transmission parameters of the RS485 interface
input of the address of the measuring instrument x
confirmation or change of the transmission parameters x
INIT-
resistant
SYSTEM settings↕
Storing
Ringbuffer
off >ON<
Storage mode
sample >AVERAGE<
Quantity Storage
one >BOTH<
Store Amplitude
off >ON<
Store c-Medium
off >ON<
Store diagnostic
off >ON<
SYSTEM settings↕
serial transmis.
SER:kill spaces
off >ON<
SER:decimalpoint
’.’ >’,’<
SER:col-separat.
’;’ >’TAB’<
Send Offline via
RS232 >RS485<
SYSTEM settings↕
Network
Device address:
0 ADR
RS485 protocol
default >SETUP<

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Flexim FLUXUS F808 A1 Series and is the answer not in the manual?

Flexim FLUXUS F808 A1 Series Specifications

General IconGeneral
BrandFlexim
ModelFLUXUS F808 A1 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals