6 Installation
FLUXUS WD 6.1 Transmitter
27
UMFLUXUS_WDV1-3EN, 2018-07-16
Transmitter with aluminum housing
Fix the wall mount (1) with 3 countersunk-head screws (3) firmly to the wall.
Use the lower claws (4) to hang the transmitter (2) onto the wall mount.
Fix the transmitter to wall mount by tightening the 2 screws (5), see Fig. 6.5 and Fig. 6.6.
Fig. 6.5: Transmitter with aluminum housing (dimensions in mm)
Fig. 6.6: Installation view
1 wall mount
2 transmitter
3 countersunk-head screw
4 hooks
5–screws
165.6
Ø 1
0.4
Ø
8.5
190.2 min. 180
1
2
5
3
5
1
4