6 Installation
FLUXUS WD 6.2 Transducers
37
UMFLUXUS_WDV1-3EN, 2018-07-16
Step 1: Dismounting of the transducer mounting fixture Variofix L
Disassemble the transducer mounting fixture Variofix L, see Fig. 6.13.
Step 2: Fixing the clasps to the tension straps
Select the installation instructions according to the supplied clasp:
Band clamp clasp
The clasp is fixed to the tension strap, see Fig. 6.14.
Quick release clasp
The clasp is fixed to the tension strap, see Fig. 6.15.
Cut the tension strap to length (pipe circumference + at least 120 mm).
Ratchet clasp
Cut the tension strap to length (pipe circumference + at least 120 mm).
Fig. 6.13: Dismounting of the transducer mounting fixture Variofix L
1–cover
2–screw
3 nut
4–rail
5 tension strap clamp
Fig. 6.14: Band clamp clasp with tension strap Fig. 6.15: Quick release clasp with tension strap
Caution!
The edge of the tension strap is very sharp.
Risk of injury!
Debur sharp edges.
Wear the required personal protective equipment. Observe the applicable rules.