6 Installation
6.2 Transducers FLUXUS WD
2018-07-16, UMFLUXUS_WDV1-3EN
38
• Insert approx. 100 mm of the tension strap into part (1) and (2) of the ratchet clasp, see Fig. 6.16 a.
• Bend the tension strap.
• Insert the tension strap into part (1) of the ratchet clasp, see Fig. 6.16 b.
• Tighten the tension strap.
• Repeat the steps for the second tension strap.
Step 3: Fixing the tensions strap to the pipe
One tension strap is fixed to the pipe, see Fig. 6.17. The second tension strap is mounted later.
Select the installation instructions according to the supplied clasp:
Band clamp clasp
• Insert the tension strap into the tension strap clamp, see Fig. 6.18.
• Position the clasp and the tension strap clamp on the pipe, see Fig. 6.17. On a horizontal pipe, mount the tension strap
clamp on the side of the pipe, if possible.
• Place the tension strap around the pipe and insert it into the clasp, see Fig. 6.20.
• Tighten the tension strap.
• Tighten the clasp screw.
Quick release clasp
• Insert the tension strap into the tension strap clamp and the metal spring, see Fig. 6.18 and Fig. 6.19.
• Position the clasp, the tension strap clamp and the metal spring on the pipe, see Fig. 6.17:
– on a horizontal pipe, mount the tension strap clamp on the side of the pipe, if possible
– mount the metal spring opposite to the tension strap clamp
Fig. 6.16: Ratchet clasp with tension strap
Fig. 6.17: Tension strap with tension strap clamp and metal spring on the pipe
1 – tension strap clamp
2–clasp
3–metal spring