6 Installation
FLUXUS WD 6.2 Transducers
45
UMFLUXUS_WDV1-3EN, 2018-07-16
6.2.2.3 Mounting with Variofix C
Scope of delivery
Mounting
When measuring in reflection arrangement, 1 transducer mounting fixture is mounted laterally on the pipe, see Fig. 6.34.
When measuring in diagonal arrangement, 2 transducer mounting fixtures are mounted on opposite sides of the pipe, see
Fig. 6.35.
In the following, the installation of 1 transducer mounting fixture in reflection arrangement is described.
Overview of the mounting steps
• step 1
dismounting of the transducer mounting fixture Variofix C
• step 2
mounting the rail
• step 3
installation of the transducers in the transducer mounting fixture Variofix C
1 × Variofix C
1 × transducer pair
1 × tension strap coil
2 × ratchet clasp
Fig. 6.34: Transducer mounting fixture Variofix C
(reflection arrangement)
Fig. 6.35: Transducer mounting fixture Variofix C
(diagonal arrangement)