If an error is encountered: an explanatory message.
Example SMS :
factory
5.3.4 “reboot”: Rebooting the concentrator
Restarting the WebdynSunPM. This command runs immediately.
Available via SMS only.
reboot
No parameters.
Return:
If successful for an SMS command: no return.
If an error is encountered: an explanatory message.
Example SMS :
reboot
5.3.5 “updateFirmware”: Concentrator software update
Retrieves rmware from a specied URL, validates it with a checksum and installs it. The command
returns a success result just before proceeding with the installation. The result of the actual installation
should be checked by the usual means of version control.
Available via MQTT/MQTTS message and SMS.
updatermware=<url>:<login>:<password>:<checksum>:<interface>
Settings:
url: URL of the le to retrieve. Accepted protocols are HTTP, HTTPS, FTP, SFTP. The port can be
specied using the address:port format.
login: Login.
password: Password.
checksum: MD5 checksum of the le for validity verication.