EasyManuals Logo

Flexitron Webdyn SunPM User Manual

Flexitron Webdyn SunPM
214 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #145 background imageLoading...
Page #145 background image
contact@webdyn.com | webdyn.com
V2.05 subject to changes | Webdyn © by Flexitron Group
145
.csv •Connection interface le
•Device denition les
•Alarm le
Delimited data le in the form of semi-
colon delimited values. (easy to use with
Excel type spreadsheet software)
.json • Command le Text le containing JSON
.lua •Script le Script le
.pem •Certicate le Certicate le
.log •Log le (compressed) Log le (compressed)
.spm •Update le Update le
4.1.1 The Conguration “CONFIG”
The concentrator can receive remote congurations in conguration les or from text messages.
Conguration File:
The WebdynSunPM concentrator needs 4 types of conguration le in text and CSV format. The les
names are the following:
<uid>_cong.ini
<uid>_daq.csv
<uid>_var.ini
<uid>_scl.ini
Where <uid> is the concentrator identier.
The current conguration is available on the remote server in the “CONFIG” directory. Whether after a
local or a remote conguration update, the concentrator sends its new conguration to the remote server
at the next connection.
Conguration les can be sent remotely using the “CONFIG” directory. Conguration les must be
uploaded or modied in the directory. On the next connection to the server, the concentrator will carry
out 2 steps:
Download the conguration le available on the server.
Apply the new conguration.