11000
24
SetPoint-4 Low
11001
25
SetPoint-5 Low
11010
11110
26
30
Not used
11111
31
Use the Expanded Command list
(Refer to Table 11-3)
B5 ... B1
Read Data
Selection
00000
0
Actual weight (if the indication is in Net)
00001
1
Gross weight
00010
2
Tare weight
00011
3
ALL Status (Refer to Table 11-1)
00100
4
Calibration Status (Refer to Table 11-2)
00101
5
Last print value
00110
01010
6
10
Not used
01011
11
CN (Label number)
01100
01110
12
14
Not used
01111
15
SetPoint-1 (High)
10000
16
SetPoint-2 (High)
10001
17
SetPoint-3 (High)
10010
18
SetPoint-4 (High)
10011
19
SetPoint-5 (High)
10100
20
Not used
10101
21
SetPoint-1 Low
Only available for Threshold and
Window feature.
Refer to sub-block 36-, page 59 to
see the availabilities.
10110
22
SetPoint-2 Low
10111
23
SetPoint-3 Low
11000
24
SetPoint-4 Low
11001
25
SetPoint-5 Low
11010
11110
26
30
Not used
11111
31
Use the Expanded Command list
(Refer to Table 11-3)
B0
New CMD
Toggle
Apply commands which are listed in this table.
(1) Write this command after writing values to 1
st
Dword, then apply this command with New CMD