EasyManua.ls Logo

FLYGT C3501 - Operational Data; Application Limits

FLYGT C3501
172 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
C3531
Voltage range Standard drive units Explosion-proof drive
units
Maximum number of
starts per hour
Up to 1.1 kV 705 715 15
735
745 15
765
775 15
805
815 15
835
845 15
865
875 15
885
895 8
905
915 8
935
945 8
965
975 8
1.2-6.6 kV
862 872 15
882
892 8
950
960 8
985
995 8
C3602
Voltage range Standard drive units Explosion-proof drive
units
Maximum number of
starts per hour
Up to 1.1 kV 735 745 15
765
775 15
805
815 15
835
845 15
865
875 15
885
895 8
905
915 8
935
945 8
1.2-6.6 kV
862 872 15
882
892 8
950
960 8
985
995 8
C3800
Voltage range Standard drive units Explosion-proof drive
units
Maximum number of
starts per hour
Up to 1.1 kV 905 915 8
935
945 8
965
975 8
1.2-6.6 kV
950 960 8
985
995 8
Operational data
Application limits
Table 40: Process data
Parameter Value
Liquid temperature Max. +40°C (+105°F)
Depth of immersion Max. 20 m (65 ft.)
pH of pumped liquid pH 6–11
Liquid density Max. 1100 kg/m
3
(9.17 lb per gal.)
Technical Reference
110 C3300/6x5, C/R3231, C3240, C3306, C3312, C3351, C3356, C3400, C3501, C3531, C3602, C3800 Installation,
Operation and Maintenance Manual

Table of Contents

Related product manuals