C3400 motor rating and performance, 60 Hz
Low voltage
Table 73: C3400, 60 Hz, low voltage
Curve /
impeller
no.
Rotations
per minute
Drive unit Voltage, V Rated
power, HP
Rated
current, A
Starting
current, A
Power
factor cos φ
1430 505 705 / 715 460 60 110 375 0.57
600 60 85 297 0.57
1230 590 705 / 715 460 60
103 395 0.61
600 60 76 282 0.63
735 / 745 460 90 148 565
0.63
600 90 116 445 0.62
765 / 775 460 120 195 725
0.63
600 120 154 590 0.61
1030 710 735 / 745 460 90
129 565 0.72
600 90 103 485 0.69
765 / 775 460 135 211 960
0.66
600 135 167 775 0.64
835 / 845 460 170 231 890
0.75
600 170 184 825 0.72
865 / 875 460 185 253 1275
0.74
600 185 210 1180 0.68
830 885 735 / 745 460 185
231 1085 0.82
600 185 178 840 0.82
765 / 775 460 230 285 1355
0.82
600 230 218 1025 0.82
835 / 845 460 335 430 2425
0.78
600 335 340 2045 0.75
865 / 875 460 415 515 2785
0.80
600 415 395 2150 0.80
630 1190 735 / 745 460 385
455 2670 0.84
600 385 345 1975 0.84
765 / 775 460 470 555 3405
0.84
600 470 435 2835 0.82