Figure 65: C3531, 50 Hz, low voltage (2 of 2)
Medium voltage
Table 58: C3531, 50 Hz, medium voltage
Curve /
impeller
no.
Rotations
per minute
Drive unit Voltage, V Rated
power, kW
Rated
current, A
Starting
current, A
Power
factor cos φ
1240 495 862 / 872 6000 110 19 82 0.62
3300 120 36 148 0.64
882 / 892 6000 130 21 94
0.67
3300 140 40 142 0.68
1040 595 862 / 872 6000 130
21 94 0.67
3300 140 40 172 0.68
882 / 892 6000 165 23 103
0.74
3300 175 44 184 0.75
6000 205 28 148 0.74
3300 225 56 276 0.75
C3531 Motor rating and performance, 50 Hz
C3300/6x5, C/R3231, C3240, C3306, C3312, C3351, C3356, C3400, C3501, C3531, C3602, C3800 Installation,