Installation
Install the pump
WARNING:
Before installing the pump, check that the cable and cable entry have not been damaged during
transportation.
Note that special rules apply to installation in explosive atmospheres.
Make sure that the pump cannot roll or fall over and injure people or damage property.
Do not install CSA-approved products in locations that are classified as hazardous in the national
electric code, ANSI/NFPA 70-2005.
NOTICE:
Do not run the pump dry.
Never force piping to make a connection with a pump.
Consult the nearest ITT representative regarding the following:
Sizing of the pump, piping station, and access frame
Choice of auxiliary equipment
Other aspects of installation
These requirements apply:
Use the pump dimensional drawing in order to ensure proper installation.
Provide a suitable barrier around the work area, for example, a guard rail.
Check the explosion risk before you weld or use electric hand tools.
Remove all debris from the inlet piping system before you install the pump.
Remove all debris from the pump sump before you install the pump.
Fasteners
WARNING:
Only use fasteners of the proper size and material.
Replace all corroded fasteners.
Make sure that all fasteners are properly tightened and that there are no missing fasteners.
The locking device
Pumps delivered in the horizontal position have a locking device for the impeller/propeller. Before you
install the pump, you must remove this locking device.