Medium voltage
Table 45: C3240, 50 Hz, medium voltage
Curve /
impeller
no.
Rotations
per minute
Drive unit Voltage, V Rated
power, kW
Rated
current, A
Starting
current, A
Power
factor cos φ
450 1490 862 / 872 6000 205 24 188 0.85
3300 215 47 360 0.84
882 / 892 3300 290 63 475
0.84
3300 345 74 505 0.85
6000 275 33 260 0.84
6000 325 39 284 0.84
0 50 100 150 200 250 300 350 400 450
l/s
0
10
20
30
40
50
60
70
80
90
100
110
120
130
m
WS000463A
450
H
Q
Figure 51: C3240, 50 Hz, medium voltage
C3240 Motor rating and performance, 50 Hz
116 C3300/6x5, C/R3231, C3240, C3306, C3312, C3351, C3356, C3400, C3501, C3531, C3602, C3800 Installation,
Operation and Maintenance Manual