Motor Data
Motor characteristics
Insulation class H (+180°C, +356°F)
Voltage variation Max. +/- 10%
Voltage imbalance between phases Max. 2%
Frequency
Pump 50 Hz 60 Hz
C3231 X X
C3240 X X
C3300 X X
C3306 X X
C3312 X X
C3351 X X
C3356 X X
C3400 X X
C3501 X X
C3531 X X
C3602 X X
C3800 X X
Monitoring with MAS
The pump is designed for use with the Flygt MAS monitoring system. The parameters tracked are chosen
by the customer and can include the following:
• Temperature (main and support bearings, stator windings)
• Vibration
• Leakage (in stator housing, junction box, and water into oil chamber)
• Power monitoring
Table 41: Parameters monitored
Description Sensor Standard or optional
Pump memory Printed circuit board for pump memory
includes a temperature sensor.
Standard
Leakage in the junction box Float Switch Leakage Sensor (FLS) Standard
Main bearing temperature Pt100 analogue temperature sensor Standard
Leakage in the stator housing Float Switch Leakage Sensor (FLS) Standard
Stator winding temperature See table below. Standard
Support bearing temperature Pt100 analogue temperature sensor Optional
Water in oil Capacitive Leakage Sensor (CLS) Optional
Vibration VIS 10 Optional
Power monitoring Separate electronic instrument using three
current transformers.
Optional
Pump current A current transformer in the control cabinet is required.
Table 42: Stator winding temperature, monitoring configurations
Drive units Sensors in coil ends of
stator windings
Additional sensors, incorporated in the stator
windings:
Always (standard) Additional option
Up to 1.1 kV One of the following
choices:
• 3 thermal switches
(standard), or
• 3 PTC-thermistors
(optional)
Pt100 analogue temperature
sensor in 1 stator winding
(standard)
Pt100 analogue temperature
sensors in 2 additional stator
windings (optional)
Technical Reference
C3300/6x5, C/R3231, C3240, C3306, C3312, C3351, C3356, C3400, C3501, C3531, C3602, C3800 Installation,
Operation and Maintenance Manual
111