Install with P-installation
In the P-installation, the pump is installed on a stationary discharge connection, and operates either
completely or partially submerged in the pumped liquid.
The following items are required:
Guide bars
Guide bar bracket for attaching the guide equipment to the access frame or to the upper part of the
sump
Level regulators or other control equipment for start, stop, and alarm
Cable holder for holding the cable and regulating the height of the level regulators
Access frame (with covers) to which the upper guide bar bracket and cable holder can be attached
Discharge connection for connecting the pump to the discharge line (the discharge connection has a
flange which fits the pump casing flange and a bracket for attaching the guide equipment)
Bushings for vibration damping between the guide bars and the discharge connection
Figure 12: P-installation
1. Provide a barrier around the pump pit; for example, a guardrail.
Installation
46 C3300/6x5, C/R3231, C3240, C3306, C3312, C3351, C3356, C3400, C3501, C3531, C3602, C3800 Installation,