Loading...
WS000487A
GPM
Q
l/s
ft
m
H
Figure 89: C3602, 60 Hz, low voltage
Medium voltage
Table 80: C3602, 60 Hz, medium voltage
Curve /
impeller
no.
Rotations
per minute
Drive unit Voltage, V Rated
power, HP
Rated
current, A
Starting
current, A
Power
factor cos φ
1440 505 862 / 872 4160 135 26 95 0.60
882 / 892 4160 180 34 118
0.61
1240 590 862 / 872 4160 190
34 153 0.63
882 / 892 4160 225 37 175
0.68
4160 300 48 208 0.70
1040 705 882 / 892 4160 270
40 184 0.75
4160 350 50 264 0.77
950 / 960 4160 310 42 217
0.82
4160 390 52 280 0.82
985 / 995 4160 440 59 340
0.81
4160 540 72 405 0.82
C3602 Motor rating and performance, 60 Hz