Medium voltage
Table 56: C3501, 50 Hz, medium voltage
Curve /
impeller
no.
Rotations
per minute
Drive unit Voltage, V Rated
power, kW
Rated
current, A
Starting
current, A
Power
factor cos φ
1230 490 862 / 872 6000 110 19 82 0.62
3300 120 36 148 0.64
1030 590 862 / 872 6000 130
19 87 0.71
3300 140 37 162 0.72
882 / 892 6000 165 23 103
0.74
3300 175 44 184 0.75
830 740 862 / 872 6000 150
19 109 0.81
3300 165 38 214 0.81
882 / 892 6000 185 23 140
0.81
3300 215 52 320 0.78
6000 235 30 179 0.79
3300 250 57 320 0.81
0 200 400 600 800 1000 1200 1400 1600 1800
l/s
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
m
1230
1030
Q
H
830
WS000479A
Figure 63: C3501, 50 Hz, medium voltage
C3501 Motor rating and performance, 50 Hz
128 C3300/6x5, C/R3231, C3240, C3306, C3312, C3351, C3356, C3400, C3501, C3531, C3602, C3800 Installation,
Operation and Maintenance Manual