Table 4: PTC-thermistor
Description Measured value Fault values
The PTC-
thermistor is a
semiconductor
device.
Resistance at normal temperature:
50-100 ohm (150-300 ohm for three
in series).
Above the tripping point, T
Ref
, the
resistance increases dramatically to
several Kohm.
An infinite value (open circuit)
indicates a fault (a wire is broken or
there is a bad contact in a connector).
A value close to zero indicates a
short circuit in the wiring.
Table 5: Pt100 sensor
Description Measured value Fault values
The Pt100 sensor is
a resistor changing
value almost linearly
with temperature.
Resistance:
100 ohm at 0ºC (32ºF)
107.79 ohm at room temperature
(20ºC, 68ºF)
138.5 ohm at 100ºC (212ºF)
For resistance data between 0–160 0ºC
(32–212ºF), see Pt100 resistance (page
32).
Never connect the Pt100 sensor to a
voltage higher than 2.5 V.
> 200 ohm (approx.) can indicate the
following situations:
Broken sensor
Bad contact
Broken lead
< 70 ohm (approx) indicates:
Short circuit.
For information on the various configurations of switches, thermistors and sensors used to monitor stator
winding temperature, see Stator temperature monitoring methods (page 31).
FLS
Table 6: Float switch sensor (FLS)
Description Measured value Fault values
The float switches are leakage
sensors located in the lower part of
the stator housing and in the
junction box.
Resistance. 2 sensor variants:
FLS:
Normal: 1530 ohm
Alarm: 330 ohm
FLS-10:
Normal: 1200 ohm
Alarm: 430 ohm
> 10% (approx.) deviation
from rated ohm values
indicates sensor fault, or fault
in the wiring.
VIS10
Table 7: Vibration sensor (VIS10)
Description Measured value Fault values
The vibration sensor located in
the junction box measures
vibrations in one direction. The
output is a 4-20 mA signal
proportional to the vibration
level.
Current, 4-20 mA
>> 20 mA indicates a short circuit.
<< 4 mA indicates a fault.
A zero value indicates a broken wire or bad
contact in a connector.
Product Description
30 C3300/6x5, C/R3231, C3240, C3306, C3312, C3351, C3356, C3400, C3501, C3531, C3602, C3800 Installation,
Operation and Maintenance Manual