10. SNMP Settings
The MFR Series router can be remotely monitored using the SNMPv2C protocol. See Sec. 4-1-8
"SNMP/SNTP Settings" for details on SNMP network settings.
Connection setting
Connect to an MFR Series main unit PC-LAN port (or the TO PC port).
After September 2011, the connector labels on MFR Series Routing Switchers have changed from
TO RU and TO PC to MFR-LAN (CPU1, 2) and PC-LAN, respectively.
SNMP MIB OID Information
MIB List
Power Supply Unit1 status
Power Supply Unit2 status
Power Supply Unit1 internal AC voltage alarm
Power Supply Unit1 internal DC voltage alarm
Fan alarm status for Power Supply Unit1 cooling fan
Power1 overheating alarm.
Power Supply Unit2 internal AC voltage alarm
Power Supply Unit2 internal DC voltage alarm
Fan alarm status for Power Supply Unit2 cooling fan
Power 2 overheating alarm.
Main unit cooling fan 1 alarm
Main unit cooling fan 2 alarm
Main unit cooling fan 3 alarm
Main unit cooling fan 4 alarm
Main unit cooling fan 5 alarm
Main unit cooling fan 6 alarm
Main unit cooling fan 7 alarm
Main unit cooling fan 8 alarm
CPU active / passive status
CPU1 internal voltage alarm
CPU2 internal voltage alarm
Master unit (main unit) status
Matrix board internal voltage alarm
Matrix board hardware version
Matrix board crosspoint error
CPU1 rear card internal voltage alarm
CPU2 rear card internal voltage alarm
mfr5kSlot
StatusList
(*1)
Name of board installed on the MFR-5000/8000
Alarm status of input and output boards
1: MFR-1000 A: MFR-1616A
3: MFR-3000 O: Other MFR MUs
5: MFR-5000
8: MFR-8000 Y: Supported, N: Unsupported