No. Function
(8) "Gas-test" button
For setting the required gas flow rate on the gas pressure regulator/for filling the
torch hosepack with shielding gas.
When the "Gas-test" button is pressed, shielding gas will flow for 30 s. Press the
button again to stop the gas flow prematurely.
(9) Adjusting dial (left)
For changing the sheet thickness, welding current and wire speed parameters as
well as changing parameters in the Setup menu
(10) "Wire threading" button
For threading the wire into the torch hosepack with no accompanying flow of gas.
While the button is being held down, the wire drive runs at feeder inching speed.
(11) Adjusting dial (right)
For changing the arc length correction, welding voltage and arc-force dynamic pa-
rameters as well as changing parameters in the Setup menu