94
dYn
dynamic - arc force dynamic correction
Unit -
Setting range 0 - 100
Factory setting 20
For further information on the dYn parameter, see the rod electrode set-up menu.
HCU
Hot-Start current
Unit %
Setting range 0 - 200
Factory setting 150
dt1
delay time 1 - time by which the start of wirefeeding is delayed after the beginning of main
current phase I
1
(cold wire-feed unit option)
Unit s
Setting range OFF / 0.1 - 9.9
Factory setting OFF
dt2
delay time 2 - Delay in the end of wirefeeding from the end of main current phase I
1
(cold wire-feed unit option)
Unit s
Setting range OFF / 0.1 - 9.9
Factory setting OFF
Fdi
Feeder inching - Feeder inching speed (cold wire-feed unit option)
Unit m/min ipm.
Setting range 1,0 - max. 39.37 - max.
Factory setting 5 197
Fdb
Feeder backward - wire withdrawal (cold wire-feed unit option)
Unit mm in.
Setting range OFF / 1 - 50 OFF / 0.04 - 1.97
Factory setting OFF OFF
For further information on the Fdb parameter, see the TIG set-up menu.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransTig 800 Job and is the answer not in the manual?

Fronius TransTig 800 Job Specifications

General IconGeneral
BrandFronius
ModelTransTig 800 Job
CategoryPortable Generator
LanguageEnglish

Related product manuals