IMPORTANT!The I
1
correction range only applies to job retrieval.
In the jobs, all the settings are permanently saved, i.e. cannot be changed. However, the
welding parameter "I-c" permits subsequent correction of the main current I
1
.
Example
The set-up parameter "I-c" has been set to 30%:
- The welding current I
1
can then be decreased or increased by up to 30%.
IMPORTANT! Every subsequent correction of the main current I
1
is reset (i.e. cancelled)
when the power source is switched off.
Io
AC current offset
Unit %
Setting range -70 to +70
Factory setting 0
For further information on the Io parameter, see the
AC / polarity reversal set-up menu.
bAL
Balance - Relationship between fusing power and cleaning action
Unit 1
Setting range -5 to +5
Factory setting 0
-5
+5
= highest fusing power, lowest cleaning action
= highest cleaning action, lowest fusing power
I-c
I (current) correction - I
1
-correction range for job retrieval
Unit %
Setting range OFF / 1 - 100
Factory setting OFF
Fd.1
Feeder 1 - wire feed speed 1 (cold wire-feed unit option)
Unit m/min ipm.
Setting range OFF / 0.1 - max. OFF / 3.94 - max.
Factory setting OFF OFF
Fd.2
Feeder 2 - wire feed speed 2 (cold wire-feed unit option)
Unit m/min ipm.
Setting range OFF / 0.1 - max. OFF / 3.94 - max.
Factory setting OFF OFF
For further information on the Fd.2 parameter, see the TIG set-up menu.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransTig 800 Job and is the answer not in the manual?

Fronius TransTig 800 Job Specifications

General IconGeneral
BrandFronius
ModelTransTig 800 Job
CategoryPortable Generator
LanguageEnglish

Related product manuals