93
EN
IMPORTANT!The I
1
correction range only applies to job retrieval.
In the jobs, all the settings are permanently saved, i.e. cannot be changed. However, the
welding parameter "I-c" permits subsequent correction of the main current I
1
.
Example
The set-up parameter "I-c" has been set to 30%:
- The welding current I
1
can then be decreased or increased by up to 30%.
IMPORTANT! Every subsequent correction of the main current I
1
is reset (i.e. cancelled)
when the power source is switched off.
Io
AC current offset
Unit %
Setting range -70 to +70
Factory setting 0
For further information on the Io parameter, see the
AC / polarity reversal set-up menu.
bAL
Balance - Relationship between fusing power and cleaning action
Unit 1
Setting range -5 to +5
Factory setting 0
-5
+5
= highest fusing power, lowest cleaning action
= highest cleaning action, lowest fusing power
I-c
I (current) correction - I
1
-correction range for job retrieval
Unit %
Setting range OFF / 1 - 100
Factory setting OFF
Fd.1
Feeder 1 - wire feed speed 1 (cold wire-feed unit option)
Unit m/min ipm.
Setting range OFF / 0.1 - max. OFF / 3.94 - max.
Factory setting OFF OFF
Fd.2
Feeder 2 - wire feed speed 2 (cold wire-feed unit option)
Unit m/min ipm.
Setting range OFF / 0.1 - max. OFF / 3.94 - max.
Factory setting OFF OFF
For further information on the Fd.2 parameter, see the TIG set-up menu.