Status Description
flashing orange CSS component failure detected.
Global Error indicator (3)
See also "iRMC-related status signals" on page 349.
Status Description
of
f No critical event detected (non-CSS component).
orange on Prefailure event detected (non-CSS component).
flashing orange Non-CSS component failure detected.
Possible causes:
– System is out of the specified temperature range
–
Defective sensor
– CPU error
– Error detected by server management software
HDD/SSD activity indicator (4)
Status Description
flashing green Data access in progress.
Power-on indicator (5)
Status Description
off The server is switched off.
green on – The server has been switched on but Power Cycle
Delay settings delay it from turning on for a
specified time.
– The server is switched on and operating normally
.
Appendix A
348 Upgrade and Maintenance Manual RX1330 M4

Table of Contents

Other manuals for Fujitsu PRIMERGY RX1330 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX1330 M4 and is the answer not in the manual?

Fujitsu PRIMERGY RX1330 M4 Specifications

General IconGeneral
ChipsetIntel C246
ProcessorIntel Pentium, Intel Celeron
Memory TypeDDR4
MemoryUp to 64 GB
Memory Slots4 DIMM slots
Drive Bays4 x 3.5-inch or 8 x 2.5-inch
Network2x 1GbE onboard, optional additional NICs
Power Supply450W
Form Factor1U
RAID Controlleroptional SAS RAID controller