Resetting the boot retry counter using iRMC web interface
â–¶
Enter the ServerView iRMC web interface.
â–¶
Select the
Server Management menu.
â–¶
The following boot retry counter settings are available under ASR&R
Options:
â–¶
Under Retry counter max specify the maximum number of attempts to
boot the OS (0 to 7).
â–¶
Under Retry counter the current number of remaining boot attempts is
displayed. Overwrite this value with the maximum number of boot
attempts specified above in order to reset the boot retry counter.
â–¶
Click Apply for the changes to take effect.
For more information on iRMC settings, see the iRMC user guides.
5.3.7 Resetting the error status after replacing memory
modules or CPU
5.3.7.1 Resetting the error status after replacing memory modules
In case of a memory error, an error counter may be set for the defective
memory module.
Important note
After replacing a defective memory module, please check if the error
counter has been reset automatically. If the memory slot is still marked
as failed, please reset the error counter manually using one of the
methods below
.
Using ServerView Maintenance Tools (Windows only)
â–¶
Launch the ServerView Maintenance T
ools:
Start > Apps > Fujitsu > Maintenance Tools
â–¶
Choose the Memory status tab.
Basic software procedures
76 Upgrade and Maintenance Manual RX1330 M4

Table of Contents

Other manuals for Fujitsu PRIMERGY RX1330 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX1330 M4 and is the answer not in the manual?

Fujitsu PRIMERGY RX1330 M4 Specifications

General IconGeneral
ChipsetIntel C246
ProcessorIntel Pentium, Intel Celeron
Memory TypeDDR4
MemoryUp to 64 GB
Memory Slots4 DIMM slots
Drive Bays4 x 3.5-inch or 8 x 2.5-inch
Network2x 1GbE onboard, optional additional NICs
Power Supply450W
Form Factor1U
RAID Controlleroptional SAS RAID controller

Related product manuals