task. Otherwise, the boot watchdog might initiate a system reboot before the
flash process is complete.
CAUTION
An incomplete firmware upgrade process may render the server
inaccessible or result in damaged/destroyed hardware.
Timer settings can be configured in the BIOS or using the ServerView iRMC
web interface.
Disabling the boot watchdog in the BIOS
▶
Enter the BIOS.
▶
Select the Server Mgmt
menu.
▶
Under Boot Watchdog set the Action setting to Continue.
▶
Save your changes and exit the BIOS.
For more information on BIOS settings, see the corresponding BIOS
Setup Utility reference manual.
Disabling the boot watchdog using the iRMC web interface
▶
Log in to the ServerView iRMC web interface.
▶
Select the
Settings menu.
▶
Open the Server Management page.
▶
In the Boot Watchdog group, check the Enable Boot Watchdog option.
The Enable Boot Watchdog option must be selected.
▶
Select Continue from the Watchdog Action list.
▶
Click Apply for the changes to take effect.
For more information on iRMC settings, see the iRMC user guides.
Basic software procedures
RX1330 M4 Upgrade and Maintenance Manual 67