EasyManuals Logo

Fujitsu PRIMERGY RX2560 M2 User Manual

Fujitsu PRIMERGY RX2560 M2
568 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #131 background imageLoading...
Page #131 background image
TX2560 M2 / RX2560 M2 Upgrade and Maintenance Manual
131
Basic software procedures
Configuring boot watchdog settings using the iRMC web frontend
Ê
Enter the ServerView iRMC web frontend.
Ê
Select the
Server Management
menu.
Ê
Under
Watchdog Settings
ensure that the check box next to Boot Watchdog is
selected. From the drop down list choose
Reset
and specify the desired
timeout delay.
Ê
Click
Apply
for the changes to take effect.
I
For detailed information on iRMC settings, refer to the "Integrated
Remote Management Controller" user guide.
5.2.10 Enabling replaced components in the system BIOS
When a processor, an expansion card, or a memory module fails, the defective
component will be set to
Disabled
or
Failed
in the system BIOS. The server will
then reboot with only the intact hardware components remaining in the system
configuration. After replacing the defective component, it needs to be re-
enabled in the system board BIOS.
Ê
Enter the BIOS.
Ê
Select the
Advanced
menu.
Ê
Select the status menu of the desired component:
– Processors:
CPU Status
I
This option is only available for multi-processor systems.
– Memory:
Memory Status
– Expansion cards:
PCI Status
Ê
Reset replaced components to
Enable
.
Ê
Save your changes and exit the BIOS.
I
For detailed information on how to access the BIOS and modify settings,
refer to your server’s "BIOS Setup Utility" reference manual.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX2560 M2 and is the answer not in the manual?

Fujitsu PRIMERGY RX2560 M2 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX2560 M2
CategoryServer
LanguageEnglish

Related product manuals