TX2560 M2 / RX2560 M2 Upgrade and Maintenance Manual
179
Hard disk drive (HDD) / solid state drive (SSD)
7.2.12.2 Removing a 2.5-inch HDD/SSD module
Ê
Remove the HDD/SSD module to be replaced from the server as described
in section "Removing a 2.5-inch HDD/SSD module" on page 176.
7.2.12.3 Installing a 2.5-inch HDD/SSD module
Ê
Install the new HDD/SSD module into the empty drive bay as described in
section "Installing 2.5-inch HDD/SSD modules" on page 173.
7.2.12.4 Concluding steps
Ê
When working on a tower server, close the HDD bay cover as described in
section "Installing accessible drive and HDD bay covers" on page 83.
Ê
"Performing a RAID array rebuild" on page 137
7.2.13 Replacing a 2.5-inch HDD SAS backplane
7.2.13.1 Preliminary steps
Ê
"Locating the defective server" on page 55
Ê
"Shutting down the server" on page 58
Ê
"Disconnecting the power cord" on page 59
Ê
"Getting access to the component" on page 61
Ê
Remove all HDD/SSD modules as described in section "Removing 2.5-inch
HDD/SSD modules" on page 175.
Ê
"Removing the system air duct" on page 91
Ê
"Removing the system fan holder" on page 93
Ê
Disconnect all cables from the defective SAS backplane.
Field Replaceable Unit
(FRU)
Hardware: 15 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver