504
Upgrade and Maintenance Manual  TX2560 M2 / RX2560 M2
Converting a tower model to a rack model
Figure 374: Securing the accessible drive cage (B)
Ê
Carefully turn the server upside down.
I
At least two people are needed to turn over a fully equipped server. 
Remove HDDs and PSUs in order to facilitate the task.
Ê
Secure the accessible drive cage with the two screws (see circles) to the 
bottom side of the server.
I
Note the correct screw positions: The screw hole on the right that has 
been used in the tower configuration remains empty.
Ê
Install the front panel module as described in section "Installing the front 
panel module" on page 440.
Ê
If applicable, install all accessible drives as described in section "Installing 
an accessible drive" on page 398.
Ê
If applicable, install an HDD extension box as described in section "HDD 
extension boxes" on page 237.
Preparing the intrusion switch
Ê
Remove the intrusion switch module as described in section "Removing the 
intrusion switch cable" on page 534.
Ê
Attach a rubber bumper (C26192-Y26-C43) to the front intrusion switch and 
reinstall the intrusion switch module as described in section "Installing the 
intrusion switch cable" on page 537.