Commonfunction
Function
Method
Callthemenuscreenfromthe
homescreenbypressingthe+key
for1second.
Select
fromthemenuwiththeJog
key.
Openthesettingscreenby
pressingtheJogkey.
(1second)
Callingthesettingscreen
WARNING
Forsafety,alwayssetthefailsafefunctions.
Ɣ5HPHPEHUWRVHWWKHWKURWWOHFKDQQHOIDLOVDIHIXQFWLRQVRWKDW
the servo moves to the maximum slow side for airplanes and
to the slow side from the hovering position for helicopters.
Crashing of the model at full high when normal radio
waves cannot be received due to interference, etc., is very
dangerous.
Ɣ,IWKHEDWWHU\IDLOVDIHLVUHVHWE\WKHWKURWWOHVWLFNLWPD\
be mistaken for an engine malfunction and will be reset at
WKURWWOHVORZDQGWKHPRGHOZLOOFRQWLQXHWRÀ\,I\RXKDYH
any doubts, immediately land.
When normal radiowaves cannot be received due
WRQRLVHDQGLQWHUIHUHQFHWKH125PRGHZKLFK
holds the servo of each channel in its position
immediately before reception was lost, or F/S (Fail
Safe) mode, which moves the servo of each channel
to a preset position, can be selected. When T-FHSS
Air is selected, the battery fail safe voltage can be
set.
ŏ:KHQWKHWKURWWOHFKDQQHOZDVUHYHUVHGE\VHUYR
UHYHUVHIXQFWLRQWKH)6GDWDLVDOVRUHYHUVHG
ŏ,IWKHUHFHLYHUEDWWHU\YROWDJH GURSVEHORZWKH
VHWYDOXHZKHQWKHIDLOVDIHPRGHZDVVHOHFWHG
WKHEDWWHU\IDLOVDIHIXQFWLRQPRYHVWKHVHUYRWRD
SUHVHWSRVLWLRQ
ŏ7KH6)+66IDLOVDIHYROWDJHLV9
ŏ:KHQWKLVIXQFWLRQZDVSHUIRUPHGUHVHWWKHEDWWHU\
IDLOVDIHIXQFWLRQE\WKHIROORZLQJPHWKRGDQG
LPPHGLDWHO\ODQG
Resetmethod:
Thebatteryfailsafefunctioncanbe
temporarilydisabled bymovingthethrottlesticktotheslowest
side.However,after30secondsthebatteryfailsafefunctionwill
returntothebatteryfailsafestate.
"F/S"
F/S
Failsafe
(Common)
Modeselection
Selectthemodeby
pressingthe+keyor
keyattheMODE
itemofeachchannel.
or
(Range)
NOR,F/S
WhenF/Smodewasselected
F/Sposition
Inthemodeselectedstate,settheF/
Spositionbyholdingthestickofthat
channelinthepositionyouwanttoset
andpresstheJogkeyfor1second.
Aconfirmationbeepingsoundsto
showthattheservopositionwas
set.
WhenusingtheB-F/Smode
① SelectACTbypressingthe+keyor
‒keyattheB-F/Sitem.
or
(Range Default)
INH,ACT INH
Failsafe
F/SPosition
Modeselect
Selectthesettingitem
withtheJogkey.
Battery-F/S:ON/OFF