APPENDIX A: FLEXANALOG OPERANDS FLEXANALOG ITEMS
L90 LINE CURRENT DIFFERENTIAL SYSTEM – INSTRUCTION MANUAL A-17
A
9415 Term 1 Vcomp Mag Volts Terminal 1 fault locator composite voltage magnitude
9417 Term 1 Vcomp Ang Degrees Terminal 1 fault locator composite voltage angle
9418 Term 2 Vcomp Mag Volts Terminal 2 fault locator composite voltage magnitude
9420 Term 2 Vcomp Ang Degrees Terminal 2 fault locator composite voltage angle
9427 Fault Loop Resistance Ohms Fault 1 fault loop resistance
9429 Fault Loop Reactance Ohms Fault 1 fault loop reactance
9447 Fault Resistance Ohms Fault 1 fault resistance
9449 Faulted Segment --- Fault 1 faulted segment
9581 PMU 1 Va Mag Volts Phasor measurement unit 1 phase A voltage magnitude
9583 PMU 1 Va Angle Degrees Phasor measurement unit 1 phase A voltage angle
9584 PMU 1 Vb Mag Volts Phasor measurement unit 1 phase B voltage magnitude
9586 PMU 1 Vb Angle Degrees Phasor measurement unit 1 phase B voltage angle
9587 PMU 1 Vc Mag Volts Phasor measurement unit 1 phase C voltage magnitude
9589 PMU 1 Vc Angle Degrees Phasor measurement unit 1 phase C voltage angle
9590 PMU 1 Vx Mag Volts Phasor measurement unit 1 auxiliary voltage magnitude
9592 PMU 1 Vx Angle Degrees Phasor measurement unit 1 auxiliary voltage angle
9593 PMU 1 V1 Mag Volts Phasor measurement unit 1 positive-sequence voltage magnitude
9595 PMU 1 V1 Angle Degrees Phasor measurement unit 1 positive-sequence voltage angle
9596 PMU 1 V2 Mag Volts Phasor measurement unit 1 negative-sequence voltage magnitude
9598 PMU 1 V2 Angle Degrees Phasor measurement unit 1 negative-sequence voltage angle
9599 PMU 1 V0 Mag Volts Phasor measurement unit 1 zero-sequence voltage magnitude
9601 PMU 1 V0 Angle Degrees Phasor measurement unit 1 zero-sequence voltage angle
9602 PMU 1 Ia Mag Amps Phasor measurement unit 1 phase A current magnitude
9604 PMU 1 Ia Angle Degrees Phasor measurement unit 1 phase A current angle
9605 PMU 1 Ib Mag Amps Phasor measurement unit 1 phase B current magnitude
9607 PMU 1 Ib Angle Degrees Phasor measurement unit 1 phase B current angle
9608 PMU 1 Ic Mag Amps Phasor measurement unit 1 phase C current magnitude
9610 PMU 1 Ic Angle Degrees Phasor measurement unit 1 phase C current angle
9611 PMU 1 Ig Mag Amps Phasor measurement unit 1 ground current magnitude
9613 PMU 1 Ig Angle Degrees Phasor measurement unit 1 ground current angle
9614 PMU 1 I1 Mag Amps Phasor measurement unit 1 positive-sequence current magnitude
9616 PMU 1 I1 Angle Degrees Phasor measurement unit 1 positive-sequence current angle
9617 PMU 1 I2 Mag Amps Phasor measurement unit 1 negative-sequence current magnitude
9619 PMU 1 I2 Angle Degrees Phasor measurement unit 1 negative-sequence current angle
9620 PMU 1 I0 Mag Amps Phasor measurement unit 1 zero-sequence current magnitude
9622 PMU 1 I0 Angle Degrees Phasor measurement unit 1 zero-sequence current angle
9623 PMU 1 Freq Hz Phasor measurement unit 1 frequency
9625 PMU 1 df dt Hz/s Phasor measurement unit 1 rate of change of frequency
9626 PMU 1 Conf Ch --- Phasor measurement unit 1 configuration change counter
10240 SRC 1 Ia THD % Source 1 phase A current total harmonic distortion
10241 SRC 1 Ia Harm[2] % Source 1 phase A current second harmonic
10242 SRC 1 Ia Harm[3] % Source 1 phase A current third harmonic
10243 SRC 1 Ia Harm[4] % Source 1 phase A current fourth harmonic
10244 SRC 1 Ia Harm[5] % Source 1 phase A current fifth harmonic
10245 SRC 1 Ia Harm[6] % Source 1 phase A current sixth harmonic
10246 SRC 1 Ia Harm[7] % Source 1 phase A current seventh harmonic
10247 SRC 1 Ia Harm[8] % Source 1 phase A current eighth harmonic
Address FlexAnalog name Units Description