CHAPTER 4: SYSTEM ADMINISTRATION SYSTEM ADMINISTRATION
MULTINET4 MULTI-PORT SERIAL SERVER & MANAGED SWITCH – INSTRUCTION MANUAL 4–71
FIGURE 4–43: Serial: Ports: Profiles
The table below describes the parameters in the Ports: Profiles screen.
Table 4–44: Ports: Profiles
Field Name Field Value
Profile Name: A user-assigned name for this profile. When you assign a profile
to a port in the 4.5.1.2 Ports: Settings screen, you select this
name in the “Profile” drop-down box.
Interface Standard: The physical interface standard used by the port. This
parameter may take one of three values:
RS-232 (RTS always asserted)
RS-232 Half (RTS asserted only when transmitting)
RS-485 2-wire (half duplex operation)
RS-485 4-wire (full duplex operation)
Default value = RS-232
WARNING: Make sure to configure the correct interface
standard before connecting to the device. Improper setup
can result in damage to the unit.