Section  9  —  Working  with  Routes 
175 
View Alarm Bands Configured in Ascent 
 
You  can  view  Alarm  Bands  configured  in  Ascent  when  you  review  the 
measurements  on  your  instrument.  To  do  this: 
1.  Press    or    Record  Review  on  the  main  menu. 
2.  Use  the  arrow  keys  on  the  left  to  select  a  recording  for  review.   
3.  Press    Expand  Navigator  repeatedly  to  expand  a  machine  until 
its  locations  and  parameter  sets  display. 
 
NOTE: When you select a parameter set, its associated recordings 
will display in the Review column. The newest recording is 
highlighted at the top of the column.   
 
4.  Press    Review  Selected  Recording.  
5.  Press    >  Press    Extended  Commands.   
6.  Use  keys   and    to  scroll  down  the  list  of  available  options  > 
Select  Alarm  Bands. 
7.  Press    —  The  Alarm  Band  or  Bands  associated  with  the 
measurement  will  display.  The  alarm  name  will  be  listed,  followed  by 
the:  
•  Measurement  type  the  alarm  applies  to  (Spectrum,  Waveform, 
Demod  Spectrum,  etc.),   
•  Frequency  range  covered  by  the  alarm  in  Orders  or  Hz/CPM. 
•  Alarm  type  (Peak  or  Power).  
 
EG: Bearing Frequencies (Spectrum) 500Hz - 900Hz (Power) 
indicates that the schedule entry includes an alarm named 
Bearing Frequencies. This alarm applies to spectra between 500 
and 900 Hz. It is checked against measurement Power values (i.e. 
the overall RMS value rather than the highest absolute peak in the 
frequency range). 
 
NOTE: When you take a measurement that exceeds the alarm 
band thresholds configured in Ascent, an alert notification will 
display on the instrument above the chart display.