Malfunctions - Diagnosis Repair GEDA
®
MINI 60 S / MAXI 120 S / MAXI 150 S
Assembly and Operating Manual 76 / 90 BL068 GB Edition 03/2015
9.1 Fault table
In the following table you will find potential faults and the appropriate
remedial action.
Fault
Cause
Remedial action
Winch does not
move
Mains plug disconnected
Mains fuse
Control fuse
Connect the mains plug
Check mains fuse and re-
place / switch on if necessary
Check / correction
(Refer to Chapter 9.2.2)
EMERGENCY STOP button
pressed
Slack rope switch operated
Overtemperature of the drive
motor
Unlock the EMERGENCY
STOP button
Tension the wire rope
(Refer to Chapter 9.2.3)
Wait until the drive motor has
cooled down and reduce the
load
Motors do not gen-
erate full power
Voltage drop of more than
10 %
Select a supply cable or ex-
tension cable with a greater
cross section
(Refer to Chapter 9.2.1)
Winch only moves
DOWN
Is the UP/overload limit
switch functional
Check/replace the
UP/overload limit switch
Tilting mechanism
is folded up
Overload protection has trig-
gered
Rope weight has moved
against the pivot arm
Reduce the load
Move downwards
Wire rope winds on
one side of the rope
drum
Vertical frame (scaffolding)
not installed vertical
Winch not adjusted horizontal
Use a spirit level to align the
vertical frame (scaffolding)
Position the winch horizontal-
ly
(Refer to Chapter 9.2.4)