EasyManua.ls Logo

Gema OptiCenter OC09 - Technical Data and Specifications

Gema OptiCenter OC09
112 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rev. 00 02/21
OptiCenter OC09 Product description
17
Technical Data
Electrical data
OptiCenter OC09
Connected load
230 V+E+N
Frequency
50/60 Hz
Protection type
IP54
Approvals
II 3 D
Pneumatic data
OptiCenter OC09
Inlet pressure
min. 6.5 bar
Water vapor content of
compressed air
max. 1.3 g/m³
Oil content of compressed air
max. 0.1 mg/m³
Powder transport
OptiCenter OC09
24 guns
Recovery
OptiFeed powder pump
OptiHopper capacity
60 liters (35 kg)
Compressed air consumption
OptiCenter OC09
Max. compressed air
consumption during cleaning (120
seconds)
200-300 Nm³/h
Coating operation
Fluidization OptiHopper +
AirMover + process air
20 Nm³/h
Consumption per applicator
5 Nm³/h
Example for 10 applicators
70 Nm³/h
Cleaning operation mode
Cleaning OptiFeed hose to
cyclone
120 Nm³/h
Cleaning conveying hose to an
applicator
30 Nm³/h
Example for 6 applicators (for
group size = 6)
180 Nm³/h

Table of Contents