Operating modes
The following operating modes are available:
– Coating
– cleaning/color change
– configuration/settings
These operating modes are described in detail in the following chapters.
The user interface of the control unit is designed with pictograms, so that
only the really essential parameters are displayed, and the operator can
can quickly find a solution.
The control unit is not in any operating mode after switching on, or after a
restart. The operating modes are selected on the panel.
Coating
This operating mode starts the coating process.
The coater decides whether the powder should be recovered or
transported into the waste.
Operating mode Coating with powder recovery (spray)
The powder is recovered in this coating mode – the powder, which does
not adhere to the object, is fed back into the powder circuit.
Operating mode Coating without powder recovery (into a
waste container - spray to waste)
There is no powder recovery in this coating mode – the powder, which
does not adhere to the object, is fed directly to the waste.
The recovery hose must be plugged in manually (connection
).
Utilization of this operating mode:
– Short coating with different powders
– If highest coating quality is required
Manual coating mode
There is no powder recovery in this coating mode – the powder, which
does not adhere to the object, is fed directly to the waste.
Utilization of this operating mode:
– For smaller coating tasks
– If highest coating quality is required
Cleaning/color change operating mode
This operating mode allows the user to select Intensive cleaning,
Quick cleaning or User-defined cleaning in the first cleaning menu. In