Decommissioning / Storage OptiCenter OC09
Physical requirements
Storage must be inside a dry building at a temperature between +5 and
+40 °C. Preferably in a cool, dry and dark space.
Do not expose to direct sunlight.
Hazard notes
There is no danger to personnel or the environment if the unit is stored
properly.
Maintenance during storage
Maintenance schedule
No maintenance schedule is necessary.
Maintenance works
During long-term storage, periodically perform a visual check.
Storage and transport of the operating panel
ATTENTION
UV light
Plastics become brittle under the influence of UV light. This
artificial aging reduces the service life of the operating panel.
Protect the operating panel from direct sunlight or other sources
of UV radiation.
ATTENTION
Risk of short-circuit
In the event of climatic fluctuations (ambient temperature or
humidity), moisture may be deposited on or inside the operating
panel. If the control panel is subjected to condensation, there is a
risk of short-circuit.
Never switch on the operating panel when condensation is
present.
If condensation is present and the operating panel has been
exposed to climatic fluctuations, allow the operating panel to
adjust to room temperature before start-up.
Do not expose the operating panel to direct heat radiation from
heaters.
Observe the ambient conditions when transporting and storing the
operating panel.
The maximum ambient temperature for storage and transport must not
exceed the specified value: