OptiCenter OC09 Maintenance / Repairs
69
Cleaning
Cleaning with compressed air!
Eye injury and bodily injury from compressed air and flying parts.
► Wear eye protection.
► DO NOT point the compressed air jet at persons.
► DO NOT point the compressed air jet at loose objects.
Hearing damage caused by sound overexposure
Peak noise levels (for a short time up to 95 db(A)) occurring during
the cleaning process may cause hearing damage.
► Do not approach the OptiCenter unless absolutely necessary!
► Wear adequate hearing protection (e.g. ear muffs per EN 352-1)!
A great deal of air is required for the cleaning procedure!
► Make sure that 6 bar is always available!
Powder can escape if the OptiHopper cover is not closed properly.
► Check that the cover fits properly
Damage to the sieve mesh tension
When using an ultrasonic sieve**, the sieve mesh tension is
damaged during cleaning!
► The OptiHopper must only be cleaned with the cover on
WITHOUT a US sieve.